Concrete precast lid

Completado Publicado Sep 11, 2013 Pagado a la entrega
Completado Pagado a la entrega

I need finite element analysis on a number of precast concrete pit lids with manholes set into them.

The first two pit lids and design loads are as follows:

1800mm x 1800mm outside dimension spanning 1500mm x 1500mm clear x 150 thick. Design load is Class B to AS3996 (80kN concentrated).

1800mm x 1800mm outside dimension spanning 1500mm x 1500mm clear x 250 thick. Design load is Class F to AS3996 (600kN concentrated).

Pit lids site on 150 thick N40 concrete pit walls on 4 sides. Pit lid concrete is N40 to Australian specs.

750 x 750 cutout in pit lid for manhole can be anywhere within the 1500 x 1500 clear span.

I need maximum bending moment (in kNm) in both directions and maximum shear (in kN) at the support perimeter to allow for design of reinforcement.

Análisis de elementos finitos

Nº del proyecto: #4916693

Sobre el proyecto

5 propuestas Proyecto remoto Activo Sep 12, 2013

Adjudicado a:

alaaelsisi

Please Check your PM.

$35 AUD en 3 días
(6 comentarios)
2.6

5 freelancers están ofertando un promedio de $250 por este trabajo

vviswanathan88

Hi, We are ANSYS FEA experts who has 30 years of R&D and design experience.

$400 AUD en 3 días
(2 comentarios)
0.8
mkeden27

regards,Let's do this, I'm ready for FEA method.

$250 AUD en 10 días
(0 comentarios)
0.0
yashirup

I can help you.

$388 AUD en 5 días
(0 comentarios)
0.0
miahmed85

I have 6 years of expertise in FEA analysis. I can complete the analysis with the provided inputs and obtain the required results.

$177 AUD en 4 días
(0 comentarios)
0.0